Product Introduction
This Bailey-type truss is built and certified to the AASHTO LRFD spec, configured specifically to carry the HL-93 design live load. If you work US or Canadian highway projects, you know HL-93: it's the AASHTO LRFD design live load, a design truck (or tandem) combined with a design lane load. We factor and check every panel, chord, web, deck member, and connection against the HL-93 combination - including impact, fatigue spectra, and deck distribution. The aashto hl-93 bailey bridge is built for this.
It's the default spec for state DOT, county, and federal highway work across North America. We hand over calculation packages, load rating reports, and construction drawings that conform to AASHTO LRFD Article 3 (Loads) and Article 6 (Steel Structures), so your approvals go smoothly.
Features
Designed and certified to AASHTO LRFD - accepted by every US state DOT and FHWA. The aashto hl-93 bailey bridge makes this practical.
HL-93 live load covers design truck, tandem, lane load, and impact factors
Supplied with stamped calculations, shop drawings, and material mill reports
A572 Gr.50 gives consistent properties per ASTM
Deck widths match US highway lane widths (12 ft lanes)
Fatigue design per AASHTO Article 6.6 delivers a 75-year service life
Galvanized per ASTM A123 matches US highway maintenance practice
Modular build needs no field welding - all bolted or pinned
Working Principle
Treat this as a simply supported modular steel truss, and load it the AASHTO way. HL-93 moves across the span as a design truck (or tandem) plus a uniform lane load. The two trusses - built from pinned modules - resist it through chord action: top chord in compression, bottom chord in tension, with diagonal webs taking the shear. The deck system spreads wheel loads sideways to both trusses using AASHTO distribution factors, and we add dynamic load allowance (15% for strength, 33% for fatigue) for vehicle impact. The aashto hl-93 bailey bridge is built for this.
Every member is sized so its factored resistance (φR_n) beats the factored load effect (Σγ_i Q_i) under the LRFD combinations. The connections - pins, bolts, welded gussets - are checked for shear, bearing, and block shear at the HL-93 factored level. Then there's fatigue: the HL-93 fatigue load (a single design truck) runs repeatedly across the span, and each detail is checked against its category from AASHTO Table 6.6.1.2.3-1. The finished bridge meets both strength and serviceability - deflection, vibration, the lot - for highway use.
Applications
Temporary detour bridges on US highway and DOT projects. The aashto hl-93 bailey bridge makes this practical.
Permanent low-volume rural road bridges in the US and Canada
Emergency FHWA-authorized disaster-relief bridges
Military reserve component (Army National Guard) bridging units
Pipeline and utility company access bridges on US right-of-way
Logging, mining, and forest road bridges in North America